Презентация на тему: ABB Welcome M Commission & Application

Реклама. Продолжение ниже
ABB Welcome M Commission & Application
ABB Welcome M Commission & Application
Overview Main Devices
Overview Main Devices
Overview Main Devices
Overview Main Devices
ABB Welcome M Commission & Application
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
Commission & Wiring
ABB Welcome M Commission & Application
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
General Ruler For Installation
ABB Welcome M Commission & Application
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
Application and solution
ABB Welcome M Commission & Application
1/92
Средняя оценка: 4.5/5 (всего оценок: 4)
Код скопирован в буфер обмена
Скачать (7264 Кб)
Реклама. Продолжение ниже
1

Первый слайд презентации: ABB Welcome M Commission & Application

June. 2013 CNDEX © ABB Group

Изображение слайда
1/1
2

Слайд 2

Content © ABB Group Overview Main Devices Commission & Wiring General Ruler of Installation Application & Solution

Изображение слайда
1/1
3

Слайд 3: Overview Main Devices

Outdoor Station © ABB Group Overview Main Devices Commission & Wiring General Ruler Application & solution Outdoor Station Indoor Station Guard Unit System Devices

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/14
4

Слайд 4: Overview Main Devices

Indoor Station © ABB Group M2200.-. Audio handset M2230.-. 4.3” Video handset M2231.-. 4.3” Video hands-free M2233.-. 7” Video hands-free Overview Main Devices Commission & Wiring General Ruler Application & solution Outdoor Station Indoor Station Guard Unit System Devices

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/5
5

Слайд 5: Overview Main Devices

Guard Unit © ABB Group M2303 Guard unit Overview Main Devices Commission & Wiring General Ruler Application & solution Outdoor Station Indoor Station Guard Unit System Devices

Изображение слайда
Изображение для работы со слайдом
1/2
6

Слайд 6: Overview Main Devices

System Devices © ABB Group M2300 System controller,8U M2301 Mini-system controller,4U M2302 Gateway,4U M2305 Switch actuator 83325/2-500 Outdoor video distributor M2304 Video distributor Overview Main Devices Commission & Wiring General Ruler Application & solution Outdoor Station Indoor Station Guard Unit System Devices

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/7
7

Слайд 7

Content © ABB Group Overview Main Devices Commission & Wiring General Ruler of Installation Application & Solution

Изображение слайда
1/1
Реклама. Продолжение ниже
8

Слайд 8: Commission & Wiring

Audio Module © ABB Group BUS Sensor PS 30VAC/DC, 1A Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator M2301 20-30VDC Release the lock (LOCK-GND) (All locks except magnetic lock) Local power supply for outdoor station Camera module

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/8
9

Слайд 9: Commission & Wiring

Audio Module © ABB Group Configure function of 1st/2nd push button: 3 4 ON MODE 3 4 ON MODE 3 4 ON MODE 3 4 ON MODE Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator Function of 1 st /2 nd pushbutton * Door lock release time 1-10s is available for the lock (LOCK-GND); While for the lock connected with “NC-NO-COM”, the time is fixed as 3s, and it can be set by entering system setting by display module.

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/12
10

Слайд 10: Commission & Wiring

Camera Module © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator Audio module CVBS GND PS_OUT PS_ IN 12VDC + - Camera GND CVBS 12VDC CVBS: Composite Video Broadcast Signal H ± 15°, V ± 15 ° CVBS GND PS_OUT PS_ IN 12VDC + - Camera GND CVBS 12VDC Option1: Camera powers on all time Option 2: Camera only powers on when surveiling

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/5
11

Слайд 11: Commission & Wiring

Other modules © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator

Изображение слайда
Изображение для работы со слайдом
1/2
12

Слайд 12: Commission & Wiring

Connect all modules together © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator BUS

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/10
13

Слайд 13: Commission & Wiring

Audio Handset © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator BUS *“Default OS: 1-9 ” can be set when entering system setting. Details please see user manual.

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/7
14

Слайд 14: Commission & Wiring

4.3” Video Handset © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator BUS M2301 Local power supply for indoor station 20-30VDC

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/11
Реклама. Продолжение ниже
15

Слайд 15: Commission & Wiring

4.3” Video Hands-free © ABB Group E.g. Address of indoor station: Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator 024 124 224 BUS M2301 Local power supply for indoor station 20-30VDC

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/18
16

Слайд 16: Commission & Wiring

7 ” Video Hands-free © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator BUS *The address of 7” video hands-free can be set from 001-250 when entering system setting. Details please see user manual.

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/11
17

Слайд 17: Commission & Wiring

Guard Unit © ABB Group Address (1-9) Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator BUS M2301 Local power supply for guard unit 20-30VDC

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/10
18

Слайд 18: Commission & Wiring

System Controller – M2300 © ABB Group System Working Mode: “One On” or “All On” Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator 100~240V L N BUS IN/OUT Technical Data: Input: 100~240V(AC) Output current: 28V(DC), 1.2A Dimension: 8U

Изображение слайда
Изображение для работы со слайдом
1/2
19

Слайд 19: Commission & Wiring

Min-system Controller – M2301 © ABB Group System Working Mode: “One On” or “All On” Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Gateway Video Distributor Switch Actuator 100~240V L N BUS IN/OUT Technical Data: Input: 100~240V(AC) Output current: 28V(DC), 0.65 A Dimension: 4U

Изображение слайда
Изображение для работы со слайдом
1/2
20

Слайд 20: Commission & Wiring

Distributor © ABB Group Indoor stations BUS IN/OUT BUS OUT Outdoor stations Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/4
21

Слайд 21: Commission & Wiring

Switch Actuator © ABB Group BUS IN/OUT Lock 30 V, 3A / Light 230 V(AC) Address (001-199) Working Mode Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway Working mode is defined as follows: MODE=00 – Extend Door Bell Mode MODE=01 – Door opening MODE=10 – Time relay MODE=11 – Toggle on/off Details see user manual. Adjust the time

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/4
22

Слайд 22: Commission & Wiring

Gateway © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway Address (01-99) BUS OUT Working mode is defined as follows: MODE=000 – Building Gateway Mode MODE=001 – Floor Gateway Mode MODE=010 – Apartment Gateway Mode MODE=011 – Auxiliary Power Supply Mode MODE=100 – Line Amplifier Mode BUS IN 1. Outdoor Station; 2. BUS IN (only in “line amplifier mode”) Working Mode

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
1/3
23

Слайд 23: Commission & Wiring

Gateway- Scenario 1 for buildings © ABB Group Building 1 Building 2 Building n Gate Station Outdoor station for building 01 Outdoor station for building 02 Outdoor station for building n C onfiguration of Gateway: MODE=000 – Building Gateway Mode Address = Building No. (<=60) Address=01 MODE=000 Address=02 MODE=000 Address=n MODE=000 Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/5
24

Слайд 24: Commission & Wiring

Gateway- Scenario 2 for floor system © ABB Group Floor n Outdoor station for building 01 Outdoor station for floor 01 Apartment 01 Apartment 02 Apartment 03 Apartment 04 Outdoor station for floor 02 Apartment 05 Apartment 06 Apartment 07 Apartment 08 Outdoor station for floor n Apartment xx Apartment xx Apartment xx Apartment xx Floor 02 Floor 01 Building 01 Address=01 MODE=001 Address=05 MODE=001 Address=xx MODE=001 C onfiguration of Gateway: MODE=001 – Floor Gateway Mode Address = Minimum address of indoor station within this floor. (<=99) Eg. Address of the gateway of 2 nd floor=05, is the starting address of first apartment of 2 nd floor:05 Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/6
25

Слайд 25: Commission & Wiring

© ABB Group Commission & Wiring Gateway – Scenario 3 for apartment system Building 01 Outdoor station for building 01 Outdoor station for apartment 03 02 01 03 04 Apartment 01 Apartment 02 Apartment 03 Apartment 04 01 02 Outdoor station for apartment 04 02 01 03 04 Apartment 05 05 Address=03 MODE=010 Address=04 MODE=010 C onfiguration of Gateway: MODE=010 – Apartment Gateway Mode Address = Apartment No. (<=99) (Configured as a normal indoor station) Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/6
26

Слайд 26: Commission & Wiring

7”VIS 7” VIS 7” VIS 7” VIS © ABB Group Commission & Wiring Gateway – Scenario 4 for auxiliary power supply C onfiguration of Gateway: MODE=011 – Auxiliary power supply mode Address = 00 Outdoor station for building 01 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS Address=00 MODE=100 Address=00 MODE=100 Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/6
27

Слайд 27: Commission & Wiring

© ABB Group Commission & Wiring Gateway – Scenario 5 for double the distance Building 1 Building 2 Gate Station Address=01 MODE=000 Address=02 MODE=000 Address=00 MODE=100 C onfiguration of Gateway: MODE=100 – Line amplifier m ode Address = 00 Max to 200m Max to 200m Max to 200m Main Devices Commission & Wiring General Ruler Application & solution Audio Module Camera Module Other Modules Audio Handset 4.3” Video Handset 4.3” Video Hands-free 7” Video Hands-free Guard Unit System Controller Video Distributor Switch Actuator Gateway

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/5
28

Слайд 28

Content © ABB Group Overview Main Devices Commission & Wiring General Ruler of Installation Application & Solution

Изображение слайда
1/1
29

Слайд 29: General Ruler For Installation

Rulers for IS — M/S ON/OFF © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Rulers for IS Rulers for multi-buildings Capacity Distance “ M/S – ON” or “M/S – OFF” : (master / slave) Only one indoor station in each apartment must be set as "Master" ('M/S on'). All additional indoor stations in the same apartment must be set as "Slave" ('M/S off'). M/S - ON M/S - OFF M/S - OFF M/S - ON M/S - OFF M/S - ON M/S - ON Apartment 02 Apartment 01 Apartment 04 Apartment 03

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/6
30

Слайд 30: General Ruler For Installation

Rulers for IS — RC ON/OFF (Audio System) © ABB Group Looping Connection Branch Line Connection RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF RC - OFF Main Devices Commission & Wiring General Ruler Application & solution Rulers for IS Rulers for multi-buildings Capacity Distance “RC-ON” or “RC-OFF”: In pure audio installations, the terminal resistor must always be deactivated ‘ RC OFF '.

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/4
31

Слайд 31: General Ruler For Installation

© ABB Group RC - OFF RC - OFF RC - ON RC - OFF RC - ON RC - ON RC - ON RC - ON RC - ON RC - ON RC - ON RC - ON RC - ON RC - OFF Rulers for IS — RC ON/OFF (Video System) General Ruler For Installation Main Devices Commission & Wiring General Ruler Application & solution Rulers for IS Rulers for multi-buildings Capacity Distance “RC-ON” or “RC-OFF”: In video installations or mixed audio and video installations, the terminal resistor must be activated on the last device of the arm ‘ RC ON '. Looping Connection Branch Line Connection

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/7
32

Слайд 32: General Ruler For Installation

© ABB Group Combined Connection Rulers for IS — RC ON/OFF ( Audio & Video System ) General Ruler For Installation Main Devices Commission & Wiring General Ruler Application & solution Rulers for IS Rulers for multi-buildings Capacity Distance RC - ON RC - OFF RC - ON RC - OFF RC - OFF RC - ON RC - ON RC - OFF RC - OFF RC - OFF RC - ON

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/7
33

Слайд 33: General Ruler For Installation

Rulers for Multi-Buildings © ABB Group RC - OFF RC - OFF RC - OFF RC - ON Looping Connection Main Devices Commission & Wiring General Ruler Application & solution Rulers for IS Rulers for multi-buildings Capacity Distance “RC-ON” or “RC-OFF”: the terminal resistor must be activated on the last device of the arm ‘ RC ON '. Building 1 Building 2 Building n Building 3

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/4
34

Слайд 34: General Ruler For Installation

Rulers for Multi-Buildings © ABB Group Branch Line Connection RC - OFF RC - ON RC - ON RC - ON RC - ON RC - OFF RC - ON Main Devices Commission & Wiring General Ruler Application & solution Rulers for IS Rulers for multi-buildings Capacity Distance “RC-ON” or “RC-OFF”: the terminal resistor must be activated on the last device of the arm ‘ RC ON '. Building 1 Building 2 Building 4 Building 3

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/5
35

Слайд 35: General Ruler For Installation

Capacity © ABB Group Main Devices Commission & Wiring General Ruler Application & solution Rulers for multi-IS Rulers for multi-buildings Capacity Distance 9 outdoor stations per building The system may include : 60 buildings 250 indoor stations per building 9 guard units per building 50 video indoor stations per system controller * 100 audio indoor stations per system controller * *Remark: only to the application that one apartments with one indoor station.

Изображение слайда
1/1
36

Слайд 36: General Ruler For Installation

© ABB Group General Ruler For Installation Insulated section: When calculating capacity, all calculations must be based on each insulated system that is only one system controller is included. Sum of segment inside one insulated section must be less than 800m. Insulated section 2 Insulated section 3 Insulated section 4 Insulated section 1 4 insulated sections are contained in the following example:

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/7
37

Слайд 37: General Ruler For Installation

© ABB Group General Ruler For Installation Only Gateway can extend the distance: When calculating distance from outdoor station(gate station) to the farthest indoor station, all calculations must be done separately if multi-gateways are involving in this communication channel B C A Distance need to be separated into 3 sections in following example. Remark: A maximum of 2 Gateways(building gateway/ apartment gateway/ floor gateway) + 2 Gateways(additional power supply mode) can be used in cascade. ( By gateways used in cascade, it means gateway crossed by an outdoor station to indoor station connection)

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/5
38

Слайд 38: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS 1 0 1 68 50 4 30 15 2 17 4 1 11 2 1 1 1 2 46 26 2 19 4 1 10 1 - 5 - - 1 2 3 24 4 1 8 1 - 2 - - 1 - - 1 3 4 2 - - 1 - - - - - - - - Additional power supply 102 82 5 47 32 2 28 15 1 19 7 1 Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ √ √ *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!! Precondition: *Unit: apartment For example: 50 means 50apartments with 1 indoor station for each apartment; 15 means 15 apartments with 2 indoor stations for each apartment.

Изображение слайда
1/1
39

Слайд 39: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS 1 0 1 68 50 4 30 20 2 17 11 1 11 6 1 1 1 2 46 26 2 19 9 1 10 3 - 5 2 - 1 2 3 24 4 1 8 1 - 2 1 - 1 1 - 1 3 4 2 - - 1 - - - - - - - - Additional power supply 102 82 5 47 37 2 28 22 1 19 14 1 Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ √ √ Precondition: *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!!

Изображение слайда
1/1
40

Слайд 40: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS 1 0 1 57 37 3 24 9 1 13 2 1 8 1 - 1 1 2 35 15 2 13 2 1 6 1 - 2 - - 1 2 3 12 1 1 2 - - 1 - - 1 - - Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ √ √ Precondition: *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!!

Изображение слайда
1/1
41

Слайд 41: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS 1 0 1 57 37 3 24 14 1 13 7 1 8 3 - 1 1 2 35 15 2 13 3 1 6 2 - 2 1 - 1 2 3 12 1 1 2 1 - 1 - - 1 - - Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ √ √ Precondition: *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!!

Изображение слайда
1/1
42

Слайд 42: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS Audio IS Audio IS Audio IS 1 0 1 80 36 21 14 1 1 2 61 26 15 9 1 2 3 43 17 9 4 1 3 4 24 8 2 1 1 4 5 6 1 1 1 Additional power supply 102 47 28 19 Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ - - √ Precondition: *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!!

Изображение слайда
1/1
43

Слайд 43: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS Audio IS Audio IS Audio IS 1 0 1 27 9 3 1 1 1 2 9 2 1 1 1 2 3 Additional power supply 49 20 11 6 Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ - - √ Precondition: *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!!

Изображение слайда
1/1
44

Слайд 44: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS 1 0 1 4 1 - - 1 1 2 1 - - - Additional power supply 49 29 3 20 5 1 11 1 1 6 1 - Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ √ √ Precondition: For kit and small building application: *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!!

Изображение слайда
1/1
45

Слайд 45: General Ruler For Installation

Capacity © ABB Group Main OS secondary OS Lock 1 IS/apartment 2 IS/apartment 3 IS/apartment 4 IS/apartment Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS Audio IS 4.3“ VIS 7" VIS 1 0 1 4 2 1 1 1 1 2 1 - - - Additional power supply 49 29 3 20 10 1 11 4 1 6 2 - Devices System System mode Outdoor station type STPS (8U) Mini-STPS (4U) Video Audio All on One on Pushbutton Keypad √ √ √ √ Precondition: *The table should be applied for each insulated system, which is only one system controller included. *If system including several system controllers, using gateway to separate the system into several insulated systems. *The data is only for reference, final data please refer to user manual!!!!!

Изображение слайда
1/1
46

Слайд 46: General Ruler For Installation

© ABB Group General Ruler For Installation Capacity Device Number Consumption IS Outdoor station 1 - Lock 1 - Indoor station(4.3") 20 20 Guard unit 1 20 Total number of IS must not exceed 50 40 The consumer units required are covered by one system controller. For example: In the realization of the systems we must consider the possibility to insert other components: one video outdoor distributor = 1 indoor station one guard unit = 20 indoor stations Example 1: One project: one indoor station/apartment, all on, pushbutton OS Example 2: One project: Two indoor stations/apartment, one on, pushbutton OS Device Number(pcs) Consumption IS Outdoor station 2 - Lock 2 - Indoor station(4.3") 20 20 Guard unit 1 20 Outdoor distributor 1 1 Total number of IS must not exceed 17*2=34 4 1 The consumer units required are not covered by one system controller. Additional power supply is needed: Two option: Option 1: add local power supply for guard unit; Option 2: add gateway+system controller for additional power supply for system

Изображение слайда
1/1
47

Слайд 47: General Ruler For Installation

Distance -- one building © ABB Group Looping Connection A Farthest indoor station Sx S1 System Dimension : Sum of all the segments of the system S1+S2+…+Sx 800m Line A=Max. distance between outdoor station and the farthest indoor station ( unit: m) Outdoor station Indoor station Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 1 480 370 350 310 300 150 140 10 450 340 320 290 280 140 130 20 410 320 300 260 250 130 120 30 370 290 270 240 230 120 110 40 330 260 240 210 200 110 90 50 290 230 210 190 180 90 80 2 1 430 340 320 280 270 140 120 10 400 310 290 260 250 130 110 20 360 280 260 230 220 120 100 30 320 250 230 210 200 100 90 40 280 220 210 180 180 90 80 50 250 190 180 160 150 80 70 3-4 1 390 300 280 250 240 120 110 10 350 270 260 230 220 110 100 20 320 240 230 200 190 100 90 30 280 210 200 180 170 90 80 40 240 180 170 150 150 80 70 50 200 150 150 130 120 60 60

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/5
48

Слайд 48: General Ruler For Installation

Distance -- one building © ABB Group Branch Line Connection Farthest indoor station A S1 S4 S5 S7 S6 S8 Sx Sx Sx Sx S2 S3 Sx System Dimension:Sum of all the segments of the system S1+S2+…+Sx 800m Line A=Max. distance between outdoor station and the farthest indoor station ( unit: m) Outdoor station Distributor Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 1 480 370 350 310 290 150 140 5 450 340 320 290 280 140 130 10 410 320 300 260 250 130 120 15 370 290 270 240 230 120 110 20 330 260 240 210 200 110 90 2 1 430 330 310 280 270 140 120 5 400 310 290 260 250 130 110 10 360 280 260 230 220 120 100 15 320 250 230 210 200 100 90 20 280 220 210 180 180 90 80 3-4 1 380 300 280 250 240 120 110 5 350 270 260 230 220 110 100 10 320 240 230 200 190 100 90 15 280 210 200 180 170 90 80 20 240 180 170 150 150 80 70

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/7
49

Слайд 49: General Ruler For Installation

© ABB Group General Ruler For Installation Distance – residential complexes Looping Connection Isulated section Isulated section Isulated section A S1 Sx L1 Lx L1 Lx C L1 Lx L2 L5 L3 L6 L4 Isulated section B

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/6
50

Слайд 50: General Ruler For Installation

© ABB Group General Ruler For Installation Distance – residential complexes Looping Connection Line A=Max. distance between outdoor station and the farthest gateway ( unit: m) Outdoor station Gateway Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 1 330 250 240 210 200 100 90 5 300 240 220 200 190 100 90 10 280 210 200 180 170 90 80 15 250 190 180 160 150 80 70 20 220 170 160 140 130 70 60 2 1 280 220 200 180 170 90 80 5 260 200 190 170 160 80 70 10 230 180 170 150 140 70 70 15 200 150 150 130 120 60 60 20 170 130 120 110 110 50 50 3-4 1 230 180 170 150 150 70 70 5 210 160 150 140 130 70 60 10 180 140 130 120 110 60 50 15 150 120 110 100 100 50 40 20 130 100 90 80 80 40 40 Line B=Max. distance between outdoor station and the gateway ( unit: m) Outdoor station Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 330 250 240 210 200 100 90 2 280 220 200 180 170 90 80 3-4 230 180 170 150 150 70 70

Изображение слайда
1/1
51

Слайд 51: General Ruler For Installation

© ABB Group General Ruler For Installation Distance – residential complexes Looping Connection System Dimension1 :Sum of all the segments of the backbone system S1+S2+…+ Sx 800m System Dimension2 :Sum of all the segments of the sub-system L1+L2+…+Lx 800m Line C=Max. distance between gateway and the farthest indoor station ( unit: m) Outdoor station Distributor Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 1 480 370 350 310 290 150 140 5 450 340 320 290 280 140 130 10 410 320 300 260 250 130 120 15 370 290 270 240 230 120 110 20 330 260 240 210 200 110 90 2 1 430 330 310 280 270 140 120 5 400 310 290 260 250 130 110 10 360 280 260 230 220 120 100 15 320 250 230 210 200 100 90 20 280 220 210 180 180 90 80 3-4 1 380 300 280 250 240 120 110 5 350 270 260 230 220 110 100 10 320 240 230 200 190 100 90 15 280 210 200 180 170 90 80 20 240 180 170 150 150 80 70

Изображение слайда
1/1
52

Слайд 52: General Ruler For Installation

Distance – residential complexes © ABB Group Branch Line Connection Sx S1 S2 A B C L1 Lx L2 L5 L3 L6 L4 S3 S4 S5 S6 Sx Isulated section Isulated section Sx Sx Sx Sx Sx Sx Sx A

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/6
53

Слайд 53: General Ruler For Installation

© ABB Group Distance – residential complexes Branch Line Connection General Ruler For Installation Line B=Max. distance between outdoor station and the gateway ( unit: m) Outdoor station Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 330 250 240 210 200 100 90 2 280 220 200 180 170 90 80 3-4 230 180 170 150 150 70 70 Line A=Max. distance between outdoor station and the farthest indoor station ( unit: m) Outdoor station Distributor Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 1 450 340 320 290 280 140 130 5 410 320 300 260 250 130 120 10 370 290 270 240 230 120 110 15 330 260 240 210 200 110 90 20 290 230 210 190 170 80 60 2 1 400 310 290 260 250 130 110 5 360 280 260 230 220 120 100 10 320 250 230 210 200 100 90 15 280 220 210 180 180 90 80 20 240 190 180 150 150 60 50 3-4 1 350 270 260 230 220 110 100 5 320 240 230 200 190 100 90 10 280 210 200 180 170 90 80 15 240 180 170 150 150 80 70 20 210 150 140 120 120 50 40

Изображение слайда
1/1
54

Слайд 54: General Ruler For Installation

© ABB Group Distance – residential complexes Branch Line Connection General Ruler For Installation Line C=Max. distance between gateway and the farthest indoor station ( unit: m) Outdoor station Distributor Coax (75 Ohm) Comelit UTP 5 RVV J-Y(ST)-Y Ø=0.75mm Ø=1mm One quarter of four pairs Ø=0.5mm 2* Two pairs of UTP 5 Ø=0.5mm Ø=1mm Ø=0.8mm Ø=0.6mm 2*0.45mm² 2*0.785mm² 2* 0.2mm² 2*0.75mm² 2*0.5mm² 2*0.28mm² 1 1 480 370 350 310 290 150 140 5 450 340 320 290 280 140 130 10 410 320 300 260 250 130 120 15 370 290 270 240 230 120 110 20 330 260 240 210 200 110 90 2 1 430 330 310 280 270 140 120 5 400 310 290 260 250 130 110 10 360 280 260 230 220 120 100 15 320 250 230 210 200 100 90 20 280 220 210 180 180 90 80 3-4 1 380 300 280 250 240 120 110 5 350 270 260 230 220 110 100 10 320 240 230 200 190 100 90 15 280 210 200 180 170 90 80 20 240 180 170 150 150 80 70 System Dimension1 :Sum of all the segments of the backbone system S1+S2+…+Sx 800m System Dimension2 :Sum of all the segments of the sub-system L1+L2+…+Lx 800m

Изображение слайда
1/1
55

Слайд 55

Content © ABB Group Overview Main Devices Commission & Wiring General Ruler of Installation Application & Solution

Изображение слайда
1/1
56

Слайд 56: Application and solution

© ABB Group 1. P lanning 2. I nstallation & W iring 3. C ommission According to user case : Choose correct devices ( modules of outdoor station; Indoor stations; system controller; the system devices which are needed.) Calculate the system consumption units, distances Planning the connection (Loop connection; Branch line connection) Install devices after reading user manuals Using the prepared wire to wiring the devices together Configure each device correctly DONE! Main Devices Commission & Wiring General Ruler Application & solution

Изображение слайда
1/1
57

Слайд 57: Application and solution

Single-family house, audio/video © ABB Group 2-wire bus line Main Devices Commission & Wiring General Ruler Application & solution Single-family house, audio/video

Изображение слайда
Изображение для работы со слайдом
1/2
58

Слайд 58: Application and solution

Single-family house, audio/video © ABB Group June 11, 2013 | Slide ‹#› 100-240V~ M2300 Add.=001 Add.=001 Add.=001 Add.=001 Add.=1 Main Devices Commission & Wiring General Ruler Application & solution Single-family house, audio/video

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/14
59

Слайд 59: Application and solution

Multi-family house, audio © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Multi-family house, audio 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
60

Слайд 60: Application and solution

100-240V~ M2300 Application and solution Multi-family house, audio © ABB Group June 11, 2013 | Slide ‹#› Remark: Up to 250 audio handsets. All consumer units required must be covered by the System Controller. Add.=xxx Add.=1 Add.=xxx Add.=001 Add.=002 M Range Product Overview Main Features Main Functions Topology and solution Multi-family house, audio

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/8
61

Слайд 61: Application and solution

Multi-family house, audio/video © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Multi-family house, audio/video 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
62

Слайд 62: Application and solution

Multi-family house, audio/video © ABB Group Remark: Up to 250 audio & video Indoor Stations. All consumer units required must be covered by the System Controller. 100~240V~ M2300 M Range Product Overview Main Features Main Functions Topology and solution Multi-family house, audio/video

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/13
63

Слайд 63: Application and solution

M ulti-indoor stations per apartment, using auxiliary power supply © ABB Group M Range Product Overview Main Features Main Functions Topology and solution One family with multi-indoor station 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
64

Слайд 64: Application and solution

© ABB Group 100~240V~ M2300 M Range Product Overview Main Features Main Functions Topology and solution One family with multi-indoor station 0 0 100-240V~ M2300 M ulti-indoor stations per apartment, using auxiliary power supply

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/17
65

Слайд 65: Application and solution

Additional power supply for 2 nd -indoor station © ABB Group M Range Product Overview Main Features Main Functions Topology and solution One family with multi-indoor station 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
66

Слайд 66: Application and solution

One family with multi-indoor station © ABB Group 100~240V~ 100~240V~ M2301 M2300 M Range Product Overview Main Features Main Functions Topology and solution One family with multi-indoor station

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/14
67

Слайд 67: Application and solution

Commercial object, audio/video © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Commercial object, audio/video 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
68

Слайд 68: Application and solution

Commercial object, audio/video © ABB Group Remark: Up to 9 Outdoor Stations All consumer units required must be covered by the System Controller. 100~240V~ M2300 Add.=1 Add.=2 Add.=3 Add.=4 M Range Product Overview Main Features Main Functions Topology and solution Commercial object, audio/video

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/10
69

Слайд 69: Application and solution

Guard unit application © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Guard unit application 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
70

Слайд 70: Application and solution

Guard unit application © ABB Group 100~240V~ 100~240V~ Remark: Up to 9 Guard for the building, and only one Master is allowed. All consumer units required must be covered by the System Controller. M2301 M2300 Add.= 1 M Range Product Overview Main Features Main Functions Topology and solution Guard unit application

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/16
71

Слайд 71: Application and solution

Apartment system, with 2nd-confirmed outdoor station © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Apartment system, with 2nd-confirmed outdoor station 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
72

Слайд 72: Application and solution

Apartment system, with 2nd-confirmed outdoor station © ABB Group 100~240V~ 0 1 9 9 100~240V~ 100~240V~ Add.=1 Add.=2 Add.=2 Add.=100 Add.=250 M Range Product Overview Main Features Main Functions Topology and solution Apartment system, with 2nd-confirmed outdoor station Add.=001 Add.=002 Add.=003 Add.=001 Add.=002 Add.=003

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/24
73

Слайд 73: Application and solution

Floor system, with outdoor station connected for each floor © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Floor system, with outdoor station connected for each floor 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
74

Слайд 74: Application and solution

Floor system, with outdoor station connected for each floor © ABB Group Remark: Up to 250 Indoor Stations. 100~240V~ 0 1 9 9 100~240V~ 100~240V~ M2300 M2301 M2301 Add.=1 Add.=2 Add.=2 M Range Product Overview Main Features Main Functions Topology and solution Floor system, with outdoor station connected for each floor Add.=001 Add.=002 Add.=003 Add.=004 Add.=099 Add.=100 Add.=101 Add.=102

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/18
75

Слайд 75: Application and solution

Auxiliary power supply for the bus © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Auxiliary power supply for the bus 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
76

Слайд 76: Application and solution

Auxiliary power supply for the bus © ABB Group Remark: Up to 250 Indoor Stations. 100~240V~ 0 0 0 0 100~240V~ 100~240V~ M2301 M2301 M2300 M Range Product Overview Main Features Main Functions Topology and solution Auxiliary power supply for the bus 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS 7” VIS

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/15
77

Слайд 77: Application and solution

Residential complexes, with looping connection © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with looping connection 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
78

Слайд 78: Application and solution

Residential complexes, with looping connection © ABB Group 100~240V~ 100~240V~ 6 0 0 1 100~240V~ Remark: All consumer units required must be covered by the System Controller. M2300 M2300 M2300 Add.=1 Add.=2 Add.=2 Add.=3 M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with looping connection

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/17
79

Слайд 79: Application and solution

Residential complexes, with branch line connection © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with branch line connection 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
80

Слайд 80: Application and solution

Residential complexes, with branch line connection © ABB Group 100~240V~ 100~240V~ 100~240V~ 0 2 0 1 Remark: All consumer units required must be covered by the System Controller. Add.=1 Add.=2 Add.=2 M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with branch line connection

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/14
81

Слайд 81: Application and solution

Residential complexes with guard unit © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Residential complexes with guard unit 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
82

Слайд 82: Application and solution

Residential complexes with guard unit © ABB Group Gate 100~240V~ 100~240V~ 100~240V~ 100~240V~ ~ 100~240V~ 0 1 0 2 Add.= 1 Add.= 2 M Range Product Overview Main Features Main Functions Topology and solution Residential complexes with guard unit Add.= 1 100~240V~

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/28
83

Слайд 83: Application and solution

Group of villas © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Group of villas 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
84

Слайд 84: Application and solution

Group of villas © ABB Group Gate 100~240V~ 100~240V~ 9 9 0 1 100~240V~ Add.=1 Add.=2 Add.=2 M Range Product Overview Main Features Main Functions Topology and solution Group of villas

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/13
85

Слайд 85: Application and solution

Residential complexes, with looping connection and long distances © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with looping connection and long distances 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
86

Слайд 86: Application and solution

Residential complexes, with looping connection and long distances © ABB Group Gate 100~240V~ 100~240V~ 100~240V~ 6 0 0 1 0 0 M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with looping connection and long distances

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/18
87

Слайд 87: Application and solution

Residential complexes, with branch line connection and long distances © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with branch line connection and long distances 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
1/2
88

Слайд 88: Application and solution

Residential complexes, with branch line connection and long distances © ABB Group Gate 100~240V~ 100~240V~ 0 2 0 1 0 0 100~240V~ 100~240V~ M Range Product Overview Main Features Main Functions Topology and solution Residential complexes, with branch line connection and long distances

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
1/22
89

Слайд 89: Application and solution

Application for more than 250 apartments per building © ABB Group M Range Product Overview Main Features Main Functions Topology and solution Application for more than 250 apartments per building 2-wire bus line

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
1/3
90

Слайд 90: Application and solution

Application for more than 250 apartments per building © ABB Group 0 1 0 0 6 0 100-240V ~ 100-240V~ 100-240V~ Gate M Range Product Overview Main Features Main Functions Topology and solution Application for more than 250 apartments per building

Изображение слайда
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом
Изображение для работы со слайдом